MIL-STD-187-721D
TABLE XIV. Control bit assignments.
5.5.3.2 Channel quality measure request.
Channel quality measure requests shall use the channel quality measure request CMD word as shown on figure 10. The Control and Epoch fields shall be encoded as described above. Each channel quality measure selector bit (see table XV) shall be set to 1 to request that the corresponding channel quality measure be reported, or to 0 to suppress reporting of that channel quality measure.
3 7 2 5 2 5 |
|||||
CMD |
1100000 (''':ALQA) |
10 |
Control |
Epoch |
CQM 1-5 |
FIGURE 10. ALQA channel quality measure request CMD format.