MIL-STD-188-164B
TABLE III. ET control and monitoring parameters.
CONTROL |
MONITORING |
Transmit gain of each upconversion function |
Transmit gain setting of each upconversion function |
Frequency setting of each upconversion function |
Frequency setting of each upconversion function |
Frequency setting of each down-conversion function |
Frequency setting of each down- conversion function |
Autotrack source (frequency band) |
Autotrack status |
Total and individual carrier power level at antenna feed |
Total and individual communications carrier power level at antenna feed |
Antenna pointing angles (azimuth and elevation relative to true north) |
Antenna pointing angles (azimuth and elevation relative to true north) |
Signal path switches (redundant equipment and waveguide switches) |
Equipment fault status |
Total transmit power level at the power amplifier output |
|
Transmit gain/loss setting from the output of each upconversion function to the input of the HPA |
|
Transmit gain setting of the power amplifier |
|
Receive gain setting from LNA input to each down-conversion function output |
|
Receive gain setting of each down- conversion function |