MIL-STD-188-164B
intended value for all RF carriers. The carrier frequency accuracy shall be maintained for a 90-day period or more without recalibration.
4.2.6 Carrier power control accuracy, step size and range. The absolute accuracy of the carrier power control attenuator(s) shall be within 1 dB of the selected attenuator value. The relative accuracy associated with the smallest step increment shall be within 0.1 dB. The minimum step size shall not exceed
0.25 dB. The minimum carrier power control range shall be
sufficient to attenuate the signal from maximum linear EIRP to
60 dBm as given by the following equation:
Min Range (dB) = Maximum-linear EIRP (dBm) - 60 (dBm)
The power control range can be met using the combination of the terminal and modem power adjustment. When a carrier power change is initiated, the controlled carrier's power shall transition monotonically and shall not induce burst errors into the controlled carrier's bit stream or into the adjacent carrier's bit stream (adjacent carrier spaced at 1.2 Rs).
4.2.7 Transmit phase linearity. Departure from phase linearity of the transmission function, when operating at any point up to the maximum-linear power, shall not exceed the following:
± 0.2 radians or less over any 2-MHz of instantaneous bandwidth.
± 0.4 radians over any 36-MHz of instantaneous bandwidth
± 0.5 radians over any 72-MHz of instantaneous bandwidth
± 0.6 radians over any 90-MHz of instantaneous bandwidth
± 0.7 radians over any 120-MHz of instantaneous bandwidth
4.2.8 Transmit amplitude response. Amplitude variations of the transmission (uplink) function at the input to the antenna feed, when operating at the maximum-linear power, shall not exceed the following:
± 0.5 dB over any 10 MHz of instantaneous bandwidth